Supermicro SuperServer 6026T-TF — Supermicro SuperServer 6026T-TF User Manual PDF (2U Rackmount Server)

Chapter 2: Server Installation Installing the Chassis Rails Position one of the fi xed chassis rail sections you just removed along the side of the 6026T-TF. Note that these two rails are left/right specifi c. Slide the rail toward the front of the chassis (see arrows in Figure 2-2) until you hear them click into place with the retention hooks on the chassis. The screw holes should now be aligned - screw the rail securely to the side of the chassis (see Figure 2-2). Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets when installng into a telco rack. Locking Tabs:

As you have seen, both chassis rails have a locking tab, which serves two functions. The fi rst is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing. Figure 2-2. Installing Chassis Rails Installing the Rack Rails Determine where you want to place the SuperServer 6026T-TF in the rack.

(See Rack and Server Precautions in Section 2-3.) Position the fi xed rack rail/sliding rail guide assemblies at the desired location in the rack, keeping the sliding rail guide facing the inside of the rack. Screw the assembly securely to the rack using the brackets provided. Attach the other assembly to the other side of the rack, making sure both are at the exact same height and with the rail guides facing inward. 2-5