Chapter 6: Advanced Chassis Setup 6-2 Control Panel The control panel (located on the front of the chassis) must be connected to the JF1 connector on the motherboard to provide you with system status indications. A ribbon cable has bundled these wires together to simplify the connection. Connect the cable from JF1 on the motherboard to the Control Panel PCB (printed circuit board). Make sure the red wire plugs into pin 1 on both connectors. Pull all excess cabling out of the airfl ow path. The LEDs inform you of system status. See "Chapter 3: System Interface" for details on the LEDs and the control panel buttons. Details on JF1 can be found in Chapter 5.

6-3 System Fans Four 8-cm fans provide all the cooling needed for the SuperServer 6026T-TF. It is very important that the chassis top cover is properly installed and making a good seal for the cooling air to circulate properly through the chassis and cool the com- ponents. See Figure 6-2. System Fan Failure Fan speed is controlled by system temperature via a BIOS setting. If a fan fails, the remaining fan will ramp up to full speed and the overheat/fan fail LED on the control panel will turn on. Replace the failed fan at your earliest convenience with the same type and model (the system can continue to run with a failed fan).

Re- move the top chassis cover while the system is still running to determine which of the four fans has failed. Replacing System Cooling Fans Replacing a Fan The system power need not be shut down since the fans are all hot-pluggable. Remove the chassis cover. 1. Press the tab on the top of the fan housing of the failed fan and remove the 2. entire housing unit. Replace the failed fan with an identical 8-cm, 12 volt fan (available from 3. Supermicro). Position the new fan at its proper place in the chassis by fi tting the fan with its housing onto the fan mounts in the chassis. A "click" can be heard if the fan (in its housing) is properly installed. 6-3