Chapter 6: Advanced Chassis Setup 6-5 Power Supply Units The SC840 has a triple redundant power supply that consists of two separate 300 watt units. One unit provides a continuous 300 watts of power to the system and the second acts as a backup, which will automatically activate if one of the first unit fails. (The backup unit is automatically determined and controlled by the power supply backplane.) Both power supplies are hot-plug units, allowing you to replace the failed unit without powering down the system. These power supply units also have an auto-switching capability, which enables them to automatically sense and operate with either 110 or 220 volt inputs.

Power Supply Failure If any one of the two power units fails, the backup unit will automatically power up and enable the system to continue operating without interrup- tion. An audible alarm will notify you of a power unit failure, which you can disable by pressing the alarm switch on the chassis control panel. The PWR Fail LED will also illuminate and remain on until the failed unit has been replaced. Replacing Power Units 1. Identifying the failed power unit: Inspect the power units mounted in the front of the chassis. The unit with the illuminated red LED indicates the failed unit and should be replaced as soon as possible.

Or, if the LED is neither red or green, check to make sure all power cables are all fully plugged into the back of the chassis. If they are, the power unit is probably bad. 2. Removing a hot-plug power unit: (See Figure 6-7) You do not need to power down the system to replace a failed power unit. To remove the failed power unit, push the locking tab on the failed unit up, then grasp the handle and pull the unit completely out. You don't need to unplug the power cable from the back of the chassis. 3. Installing a new hot-plug power unit: Replace the failed unit with another unit of the same wattage. It is highly recommended that both power units are exactly the same.

Gently but firmly push the new unit all the way into the open bay. Secure it by pushing the locking tab downward. The green LED on the power supply unit should illuminate to show that it has power and is operational. 6-11