Supermicro 7047R-TXRF — Supermicro SuperServer 7047R-TXRF User's Manual PDF Download

S UPER S ERVER 7047R-TXRF User's Manual A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connec- tions other than the direct connections to the branch circuit (i.e. the use of power strips, etc.). Reliable Ground 2-4 Installing the Chassis onto a Rack This section provides information on installing the SC747 chassis into a rack unit with the optional 4U 17.2" width rail set (MCP-290-00059-0B). There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly.

You should also refer to the installation instructions that came with the rack unit you are using. Notes: The outer rail is adjustable from 26" to 38.25". The MCP-290-00059-0N rail kit is an optional accessory. Removing the Chassis Cover and Feet The SC747 chassis is shipped with the chassis cover and feet pre-installed. Both the feet and cover must be removed for before installing the rails. Removing the Chassis Top Cover 1. Locate the chassis cover lock (blue lever) at the rear of the chassis cover. 2. Slide the chassis cover lock to the right and push chassis cover forward. 3. Lift the chassis top cover off the chassis. Removing the Chassis Feet 1.

Place the chassis on its side with the chassis side cover facing upward. 2. Remove the screw holding the chassis foot in place. 3. The foot lock is a tab located in the center of the foot that prevents the foot from sliding. Using a flat head screwdriver, gently lift the foot lock upward and slide the foot toward the rear of the chassis. 4. Repeat steps 2 and 3 with each remaining foot. 2-4