Chapter 5: Advanced Serverboard Setup NIC1/NIC2 LED Indicators The NIC (Network Interface Controller) LED connection for GLAN port 1 is located on pins 11 and 12 of JF1, and the LED connection for GLAN Port 2 is on Pins 9 and 10. Attach the NIC LED cables here to display network activity. Refer to the table on the right for pin definitions. Overheat (OH)/Fan Fail/PWR Fail/ UID LED Connect an LED cable to pins 7 and 8 of Front Control Panel to use the Overheat/Fan Fail/Power Fail and UID LED connections. The Red LED on pin 7 provides warnings of overheat, fan failure or power failure. The Blue LED on pin 8 works as the front panel UID LED indicator.
The Red LED takes precedence over the Blue LED by default. Refer to the table on the right for pin definitions. Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin definitions. Reset Button Reset Button Pin Definitions (JF1) The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a hardware reset switch on the computer case. Refer to the table on the right for pin definitions.
Pin# Definition 3 Reset 4 Ground 5-15 GLAN1/2 LED Pin Definitions (JF1) Pin# Definition 9 Vcc 10 NIC 2 LED 11 Vcc 12 NIC 1 LED OH/Fan Fail/ PWR Fail/Blue_UID LED Pin Definitions (JF1) Pin# Definition 7 Red LED-Cathode/OH/Fan Fail/ _ Power Fail5.5V.SB 8 Blue UID LED _ OH/Fan Fail/PWR Fail LED Status (Red LED) State Definition Off Normal On Overheat Flashing Fan Fail PWR Fail LED Pin Definitions (JF1) Pin# Definition 5 3.3V 6 PWR Supply Fail