SuperServer 7088B-TR4FT User's Manual System Cooling Eight hot-swapable 9-cm counter-rotating fans at the rear of the chassis provide the cooling for the system. Each fan unit is made up of two fans joined back-to-back, which rotate in opposite directions. This counter-rotating action generates exceptional airflow and is effective in dampening vibration levels. Replacing Fans Fan speed is controlled by system temperature via IPMI. If a fan fails, the remaining fans will ramp up to full speed. Replace any failed fan at your earliest convenience with the same type and model (the system can continue to run with a failed fan). Replacing a System Fan 1.
Inspect the rear of the chassis to determine which fan requires changing. 2. Squeeze both release tabs on the fan simultaeously and gently pull the fan from the housing (see figure below). The fan's wiring will automatically detach. 3. Place the new fan into the vacant fan space and push in until it clicks into place. Release Tab Release Tab Figure 3-18. Replacing a System Fan 48