Supermicro 8045C-3R — Super Micro 8045C-3R Server User & Service Manual PDF

Chapter 6: Advanced Chassis Setup Figure 6-7. Adding a Component in a 5.25" Drive Bay 6-5 Power Supply The SuperServer 8045C-3R has a redundant 1200 watt power supply consisting of two power modules. (A third may be added for triple redundancy.) Each power module has an auto-switching capability, which enables it to automatically sense and operate at a 100V - 240V input voltage. Power Supply Failure Under normal operation, both of the modules are operating. If either of the two power supply modules fail, the other module will take the full load and allow the system to continue operation without interruption.

The PWR Fail LED will illuminate and remain on until the failed unit has been replaced. Replacement units can be ordered directly from Supermicro. The hot-swap capability of the power supply modules allows you to replace the failed module without powering down the system. Removing/Replacing the Power Supply You do not need to shut down the system to replace a power supply unit. The redundant feature will keep the system up and running while you replace the failed hot-swap unit. Replace with the same model (see Appendix D). Removing the Power Supply 1. First unplug the power cord that corresponds to the failed power supply unit.

The power cords are oriented the same as the modules are (the left/top power cord corresponds to the left/top power module). 2. Depress the locking tab on the power supply unit and pull the unit straight out by the handle. See Figure 6-8. 6-9