Supermicro 8046B-TRLF — Supermicro 8046B-TRLF Server User's Manual PDF Download

S UPER S ERVER 8046B-TRLF User's Manual 2-4 Installing the System into a Rack This section provides information on installing the system into a rack unit. Rack installation requires the use of the optional rackmount kit If the system has already been mounted into a rack or if you are using it as a tower, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. The following is a guideline for installing the server into a rack with the rack rails provided in the rackmount kit. You should also refer to the installation instructions that came with the rack unit you are using. Note:

The outer rail is adjustable from 26" to 38.25". Removing the Chassis Cover and Feet The SC748 chassis is shipped with the chassis cover and feet pre-installed. Both the feet and cover must be removed for before installing the rails. Removing the Chassis Top Cover Locate the chassis cover lock (blue lever) at the rear of the chassis cover. 1. Slide the chassis cover lock to the right and push chassis cover forward. 2. Lift the chassis top cover off the chassis. 3. Removing the Chassis Feet Place the chassis on its side with the chassis side cover facing upward. 1. Remove the screw holding the chassis foot in place. 2.

The foot lock is a tab located in the center of the foot that prevents the foot 3. from sliding. Using a fl at head screwdriver, gently lift the foot lock upward and slide the foot toward the rear of the chassis. Repeat steps 2 and 3 with each remaining foot. 4. 2-4