S UPER S ERVER 8046B-TRLF User's Manual 3-3 Control Panel LEDs The control panel located on the front of the SC748TQ-R1400 chassis has fi ve LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take. Power Fail Indicates a power supply module has failed. This should be accompanied by an audible alarm. A backup power supply module will take the load and keep the system running but the failed module will need to be replaced. Refer to Chapter 6 for details on replacing failed power supply modules.
This LED should be off when the system is operating normally. Overheat/Fan Fail fl ashing) it indicates an overheat condition, which may be caused by cables ob- When this LED fl ashes it indicates a fan failure. When on continuously (on and not structing the airfl ow in the system or the ambient room temperature being too warm. Check the routing of the cables and make sure all fans are present and operating normally. You should also check to make sure that the chassis covers are installed. Finally, verify that the heatsinks are installed properly (see Chapter 5). This LED will remain fl ashing or on as long as the overheat/fan fail condition exists.
2 NIC2 Indicates network activity on LAN2 when fl ashing . 3-2