Chapter 5: Advanced Serverboard Setup Overheat/Fan/Pwr Fail/UID LED Connect an LED to pins 7 and 8 of JF1 to use the Overheat/Fan Fail/ Power Fail/UID LED functions. The red LED on pin 7 provides warning of overheat, fan failure or power failure. The blue LED on pin 8 works as the front panel UID LED indicator. The red LED takes precedence over the blue LED by default. Refer to the table on the right for pin defi nitions. NIC2 (JLAN2) LED The LED connections for JLAN2 are on pins 9 and 10 of JF1. Attach an LED cable to display network activ- ity. See the table on the right for pin defi nitions. NIC1 (JLAN1) LED The LED connections for JLAN1 are on pins 11 and 12 of JF1.

Attach an LED cable to display network activ- ity. See the table on the right for pin defi nitions. HDD LED The HDD LED connection is located on pins 13 and 14 of JF1. This LED is used to display all IDE and SATA activity. See the table on the right for pin defi nitions.

5-15 OH/Fan Fail/ Pwr Fail/UID LED Pin Defi nitions (JF1) Pin# Defi nition 7 Red + (Blue LED Cathode) 8 Blue (OH/Fan Fail/PWR Fail/ UID LED) OH/Fan Fail Indicator Status State Defi nition Off Normal On Overheat Flash- ing Fan Fail NIC2 LED Pin Defi nitions (JF1) Pin# Defi nition 9 Activity 10 Link NIC1 LED Pin Defi nitions (JF1) Pin# Defi nition 11 Activity 12 Link HDD LED Pin Defi nitions (JF1) Pin# Defi nition 13 3.3V 14 HD Active