S UPER S ERVER 8046B-TRLF User's Manual 6-4 Drive Bay Installation Hard Drives The hard drives are mounted in drive carriers to simplify their installation and remov- al from the chassis. These carriers also help promote proper airfl ow for the drives. For this reason, even empty carriers without hard drives installed must remain in the chassis. A total of fi ve SATA drives may be housed in the SC748TQ-R1400B chassis. The drive IDs are preconfi gured as 0 through 4 in order from right to left (or from bottom to top if rackmounted). Installing/Removing Hot-swap Hard Drives The hard drive carriers are all easily accessible at the front of the chassis.
These drives are hot-swappable, meaning they can be removed and installed without powering down the system. Push the release button on the carrier located beside the drive LEDs. 1. Swing the handle fully out and then use it to pull the drive straight out. 2. Note: Your operating system must have RAID support to enable the hot-swap capability of the hard drives. Mounting a Hard Drive in a Drive Carrier The hard drive carriers help to promote proper airfl ow for the system. For this reason, even carriers without hard drives must remain in the server. Insert the drive into the carrier with the printed circuit board side facing down 1. so that the mounting holes align with those in the carrier.
Secure the drive to the carrier with four screws (see Figure 6-6). 2. SATA Backplane The hard drives plug into a SATA backplane on the CSE-M35P mobile rack, which houses the hard drive bays. The drive data cables must be connected from the serverboard to the appropriate connectors on the backplane. There are also two power connectors on the backplane - both should be connected. 6-6