Supermicro 8046B-TRLF — Supermicro 8046B-TRLF Server User's Manual PDF Download

Chapter 6: Advanced Chassis Setup Figure 6-7. Adding a Component in a 5.25" Drive Bay Hard Drive Tray Hard Drive 6-5 Power Supply The SuperServer 8046B-TRLF has a redundant 1400 watt power supply consisting of two power modules. (A third may be added for triple redundancy.) Each power module has an auto-switching capability, which enables it to automatically sense and operate at a 100V - 240V input voltage. Power Supply Failure If either of the two power supply modules fail, the other module will take the full load and allow the system to continue operation without interruption. The PWR Fail LED will illuminate and remain on until the failed unit has been replaced.

Replace- ment units can be ordered directly from Supermicro. The hot-swap capability of the power supply modules allows you to replace the failed module without powering down the system. Removing/Replacing the Power Supply You do not need to shut down the system to replace a power supply unit. The redundant feature will keep the system up and running while you replace the failed hot-swap module. Replace with the same model (see Appendix B). 6-9