Chapter 5: Advanced Serverboard Setup Watch Dog Enable/Disable Jumper JWD controls the Watch Dog function. Watch Dog is a system monitor that can reboot the system when a software application hangs. Jumping pins 1-2 will cause WD to reset the system if an application hangs. Jumping pins 2-3 will generate a non-maskable interrupt signal for the application that hangs. See the table on the right for jumper settings. Watch Dog must also be enabled in BIOS. Note: When enabled, the user needs to write their own application software in order to disable the Watch Dog Timer.

Manufacturer's Mode Close pins 2 and 3 of jumper JPME2 allows the user to flash the system firmware from a host server in order to modify system settings. See the table on the right for jumper settings. BMC Enable Jumper JPB1 allows you to enable the embedded the ASpeed AST 2400 BMC (Baseboard Management) Controller to provide IPMI 2.0/KVM support on the motherboard. See the table on the right for jumper settings.

5-21 Watch Dog Jumper Settings Jumper Setting Definition Pins 1-2 Reset Pins 2-3 NMI Open Disabled ME Mode Select Jumper Settings Jumper Setting Definition Pins 1-2 Normal Pins 2-3 Manufacture's Mode BMC Enable Jumper Settings Jumper Setting Definition Pins 1-2 Enabled Pins 2-3 Disabled