SuperStorage Server 6028R-E1CR24(N/L) A sensor on the backplane will issue a warning at 45°C. Overheating is critical at 49°C. There are several possible responses if the system overheats. Overheating If the server overheats: 1. Use the LEDs to determine the nature of the overheating condition. 2. Confirm that the chassis covers are installed properly. 3. Check the routing of the cables and make sure all fans are present and operating normally. 4. Verify that the heatsinks are installed properly. 3-4 Drive Carrier LEDs The chassis includes externally accessible SAS/SATA/NVMe drives. Each drive carrier displays two LED indicators: an activity indicator and a status indicator.
The status indicator functions in RAID configurations. For non-RAID configurations, it remains off. See the table below for details.
3-4 LED Color Blinking Pattern Behavior for Device Activity LED Blue Blinking I/O activity Blue Solid On Idle SAS/NVMe drive installed Off Off Idle or SATA drive Status LED Red Solid On Failure of drive with RSTe support Red Blinking at 1 Hz Rebuild drive with RSTe support Red Blinking with two blinks and one stop at 1 Hz Hot spare for drive with RSTe support Red On for five seconds, then off Power on for drive with RSTe support Red Blinking at 4 Hz Identify drive with RSTe support Green Solid On Safe to remove NVMe device Amber Blinking at 1 Hz Attention state—do not remove NVMe device