Chapter 4: Motherboard Connections Overheat (OH)/Fan Fail Connect an LED cable to pins 7 and 8 of JF1 to use the Overheat/Fan Fail LED connections. The LED on pin 8 provides warnings of overheat or fan failure. NIC1/NIC2 (LAN1/LAN2) The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11 and 12 of JF1, and the LED connection for LAN Port 2 is on Pins 9 and 10. Attach the NIC LED cables here to display network activity. HDD LED/UID Switch The HDD LED/UID Switch connection is located on pins 13 and 14 of JF1. Attach a cable to Pin 14 to show hard drive activity status. Attach a cable to Pin 13 to use UID switch. Refer to the table below for pin definitions.
51 OH/Fan Fail Indicator Status Status Definition Off Normal On Overheat Flashing Fan Fail OH/Fan Fail LED Pin Definitions (JF1) Pin# Definition 7 Blue LED 8 OH/Fan Fail LED LAN1/LAN2 LED Pin Definitions (JF1) Pin# Definition 9 NIC2 Activity LED 10 NIC2 Link LED 11 NIC1 Activity LED 12 NIC1 Link LED HDD LED Pin Definitions (JF1) Pin# Definition 13 3.3V Standby/UID Switch 14 HDD Active