Chapter 7: BIOS in its newer processors. The basic concept is that each CPU is embedded by a unique temperature information that the motherboard can read. This ‘Temperature Threshold’ or ‘Temperature Tolerance’ has been assigned at the factory and is the baseline by which the motherboard takes action during different CPU temperature conditions (i.e., by increasing CPU Fan speed, triggering the Overheat Alarm, etc). Since CPUs can have different ‘Tem- perature Tolerances’, the installed CPU can now send its ‘Temperature Toler- ance’ to the motherboard resulting in better CPU thermal management.

Supermicro has leveraged this feature by assigning a temperature status to certain thermal conditions in the processor (Low, Medium and High). This makes it easier for the user to understand the CPU’s temperature status, rather than by just simply seeing a temperature reading (i.e., 25 o C). The information provided above is for your reference only. For more information on thermal management, please refer to Intel’s Web site at www.Intel.com. IOH Temperature This feature displays the absolute Input/Output Hub (IOH) temperature (i.e., 51 o C). System Temperature This feature displays the absolute system temperature (i.e., 34 o C).

Fan1 ~ Fan 6 Reading This feature displays the fan speed readings from fan interfaces Fan1 through Fan6. Fan Speed Control Modes This feature allows the user to decide how the system controls the speeds of the onboard fans. The CPU temperature and the fan speed are correlative. When the CPU on-die temperature increases, the fan speed will also increase for effective system cooling. Select Full Speed to allow the onboard fans to run at full speed (of 100% Pulse Width Modulation Duty Cycle) for maximum cooling. The Full Speed setting is recommended for special system confi guration or debugging.

Select Performance for the onboard fans to run at 70% of the Initial PWM Cycle for better system cooling. The Performance setting is recommended for high-power-consum- ing and high-density systems. Select Balanced for the onboard fans to run at 50% of the Initial PWM Cycle in order to balance the needs between system cooling and power saving. The Balanced setting is recommended for regular systems with normal hardware confi gurations. Select Energy Saving for the onboard fans to run at 30% of the Initial PWM Cycle for best power effi ciency and maximum quietness. The Options are: Full Speed/FS (@100% of PWM Cycle), Performance/PF (@70% 7-19