Supermicro SuperWorkstation 5037A-I — Supermicro SuperWorkstation 5037A-I User Manual PDF Download

S uper W orkstation 5037A-I User's Manual 6-3 Front Control Panel The front control panel must be connected to the JF1 connector on the motherboard to provide you with system status and alarm indications. A ribbon cable has bundled these wires together to simplify this connection. Connect the cable from JF1 on the motherboard (making sure the red wire plugs into pin 1) to the appropriate comnnector on the front control panel PCB (printed circuit board). Pull all excess cabling over to the control panel side of the chassis. The LEDs on the control panel inform you of system status - see Figure 6-2 for details. See Chapter 5 for details on JF1. Figure 6-2.

Front Control Panel LEDs Indicates IDE device and hard drive activity. On the SC743TQ-1200B-SQ, this LED indicates hard drive activity when flashing. HDD NIC 1 Indicates network activity on the LAN port. Overheat/Fan Fail When this LED flashes, it indicates a fan failure. When on continuously it indicates an overheat condition (see Chapter 3 for details). 6-4