Supermicro SuperWorkstation 5037A-IL — SuperWorkstation 5037A-IL User's Manual

S uper W orkstation 5037A-IL User's Manual Serial Port Console Redirection COM1/COM2 Console Redirection Use this feature to enable console redirection for COM1 and COM2 ports. The op­ tions are Enabled and Disabled . Console Redirection Settings Configure the following options for the Console Redirection Settings. The most common settings are set as default: Terminal Type : Select ANSI, VT100, VT100+ , or VT-UTF8 Bits per Second (BPS): 9600, 19200, 38400, 57600, or 115200 Data Bits: 8 or 7 Parity: None , Even, Odd, Mark, or Space Stop Bits: 1 or 2 Flow Control: None or Hardware RTS/CTS VT-UTF8 Combo Key Support: Enabled or Disabled Recorder Mode: Disabled or Enabled Resolution 100x31:

Enabled or Disabled Legacy OS Redirection Resolution: 80x25 or 80x24 puTTY Keypad: VT100 , LINUX, XTERM6, SCO,ESCN, VT400 Serial Port for Out-of-Band Management/ Windows Emergency Management Services (EMS) Use this feature to enable console redirection for Serial Port for Out-of-Band Man­ agement and Windows Emergency Management Services (EMS). The options are Enabled and Disabled . Console Redirection Settings Configure the following options for the Console Redirection Settings. The most common settings are set as default: Out-of-Band Mgmt Port: COM1 , COM2, COM3 (PCI, Bus0, Dev0, Func0) Terminal Type : Select ANSI, VT100, VT100+, or VT-UTF8 Bits per Second (BPS):

9600, 19200, 57600, or 115200 Data Bits: 8 or 7 Parity: None , Even, Odd, Mark, or Space Stop Bits: 1 or 2 7-14