S uper W orkstation 7045A-WT User's Manual 6-3 System Fans Two 8-cm PWM chassis cooling fans (located in the center of the chassis) provide cooling airfl ow while one 9-cm exhaust fan expels hot air from the chassis. The fans should all be connected to headers on the serverboard (see Chapter 5). Each power supply module also has a cooling fan. Fan Failure Under normal operation, the chassis fans, the exhaust fan and the power supply fans run continuously. The chassis fans are located in the two middle housings. They are hot-swappable and can be replaced without powering down the system.

Replacing Chassis Cooling Fans Removing a Fan First locate the failed chassis fan by removing the top/left chassis cover (see 1. Chapter 2 for details). Locate the fan that has stopped working. Depress the locking tab on the failed fan: on a chassis fan, push the tab on 2. the side of the housing inward, on the exhaust fan push down on the colored tab. With the tab depressed, pull the unit straight out (see Figure 6-3). The wiring 3. for these fans has been designed to detach automatically. Installing a New Fan Replace the failed fan with an identical one (available from Supermicro) 1. Install it in the same position and orientation as the one you removed; it 2.

should click into place when fully inserted. Check that the fan is working then replace the top/left side chassis panel. 3. 6-4