Supermicro SuperWorkstation 7047GR-TRF — Supermicro SuperWorkstation 7047GR-TRF User's Manual PDF

Chapter 6: Advanced Chassis Setup 6-4 Power Supply The SC747 chassis has a 1620W (redundant) power supply. This power supply is auto-switching capable. This enables it to automatically sense and operate at a 100v to 240v input voltage. An amber light will be illuminated on the power supply when the power is off. An illuminated green light indicates that the power supply is operating. Power Supply Failure If the power supply module fails, the system will shut down and you will need to replace the module. Replacements can be ordered directly from Supermicro (see contact information in the Preface).

As there is only one power supply module in the system, power must be completely removed from the workstation before removing and replacing the power supply for whatever reason. Replacing the Power Supply With a redundant power supply, the system automatically switches to the second power supply if the fi rst should fail. Replacing the Power Supply 1. Power down the chassis and unplug the power cord. If your chassis includes a redundant power supply (at least two power modules), you can leave the workstation running and remove only one power supply. 2. Push the release tab (on the back of the power supply) as illustrated in Figure 6-5. 3. Pull the power supply out using the handle provided.

4. Replace the failed power module with the exact same model (available from Supermicro). 5. Push the new power supply module into the power bay until you hear a click. 6. Plug the AC power cord back into the module and power up the workstation. 6-5