Chapter 2: Rack Intallation Rack Installation Chapter 2 This chapter provides instructions for preparing and mounting your chassis in a rack. By default, the chassis is shipped configured as a tower. The tower top cover and bottom feet must be removed to mount in a rack. Also, the control panel/drive module should be rotated 90 degrees. See Chapter 6 for this procedure. 2-1 Unpacking the System You should inspect the box the chassis was shipped in and note if it was damaged in any way. If the chassis itself shows damage, file a damage claim with the carrier who delivered it. Mounting rails are optional for this system. Be sure you have received the correct rail kit for your server.
2-2 Preparing for Setup Decide on a suitable location for the rack unit that will hold your chassis. It should be a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. A nearby grounded power outlet. is required Choosing a Setup Location Leave at least 25 inches clearance in front of the rack to open the front door completely. Leave approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and access for servicing. It should be a restricted access location, such as a dedicated equipment room or a service closet. 2-1