8.2.12 BUS RELEASE FROM INFORMATION PHASE (TARGET) PRELIMINARY NAME DESCRIPTION MIN TYP MAX UNITS tTDB TGS & SBEN Turn-off from BSYOUT off 225 ns tDOS Driver Turn-off set-up to TGS off 0 ns BSYIN \~--------------------- BSYOUT i\ SELIN SELOUT TGS iE=--t TDB, SBO-7, SBP '" OUT OR IN / IN ~tDOS " oE-- " IN ~t DOS '" ~ " IN ::;j t DOS '" ~ REO OUT 1/0, elD MSG OUT / SBEN ARB 48