Synonym: GETCNT - Read a counted String from a logical Block Hex Code: S9X33 SlX33 DESCRIPTION: The GETCNT command copies a counted string from a' logical block of a unit to the I/O buffer. The string is delimited with the standard string delimiter (default = $99). The Parameter at offset 4 in CMDRAM holds the offset from the logical block base to the first byte of the requested string. PARAMETER PASSING: IN: CMDRAM Offset Size Meaning 9 2 4 8 12 14 w W L L W W Command/Target ID String length First Byte Location in Block Logical Block Address Logical Unit Number Reserved for interprocessor cation communi- OUT:
CMDRAM Offset Size Meaning 9 2 4 8 12 14 w W L L W W Status/Error return code Extended Error Message Pointer to String Unused/reserved Unused/reserved Reserved for interprocessor cation comnmn i- POSSIBLE RETURN CODES: 8999, 9999 = Successful, no error 8992, 9992 = Address error 8996, 9996 = Missing or invalid parameter 3-31