FORCE Computers SYS68K/ISCSI-1 — SYS68K/ISCSI-1 User's Manual

REQUEST SENSE The REQUEST SENSE command requests that the target transfer sense data to the initiator. COMMAND BLOCK: +-+-+-+-+-+-+-+-+ 17161514131211101 +-+-+-+-+-+-+-+-+ BIT' 10 0 0 0 0 0 1 11 +-+-+-+-+-+-+-+-+ OPCODE ILluINI0 0 0 0 01 +-+-+-+-+-+-+-+-+ 10 0 0 0 0 0 0 01 +-+-+-+-+-+-+-+-+ 10 0 0 0 0 0 0 01 +-+-+-+-+-+-+-+-+ 10 0 0 0 0 1 0 01 +-+-+-+-+-+-+-+-+ ALLOCATION LENGTH 10 0 0 0 0 0 0 01 +-+-+-+-+-+-+-+-+ SENSE DATA: The REQUEST SENSE command always returns a block of 4 bytes of information. BYTE MEANING 00 Sense key, error information 01 Logical block address (MSB) 02 Logical block address 03 Logical block address (LSB) SENSE KEYS $00 NO SENSE.

$01 RECOVERED ERROR $02 NOT READY $03 MEDIUM ERROR $04 HARDWARE ERROR $05 ILLEGAL REQUEST $06 not used $07 not used $08 not used $09 not used $0A not used $0B ABORTED COMMAND $0C not used $0D VOLUME OVERFLOW $0E not used $0F reserved 3-71