5.2 The SCSIbus Signal Description There are a total of eighteen signals. Nine are used for control, and nine are used for data. (Data signals include the parity signal option). These signals are described as follows: BSY (BUSY) An "OR-tied" signal that indicates that the bus is being used. SEL (SELECT) A signal used by an initiator to select a target or by a target to reselect an initiator. C/D (CONTROL/DATA) A signal driven by a target that indicates whether CONTROL or DATA information is on the data bus. True indicates CONTROL. I/O (INPUT/OUTPUT) A signal driven by a target that control the direction of data movement on the data bus with respect to an initiator.

True indicates input to the initiator. This signal is also used to distinguish between SELECTION and RESELECTION phases. MSG (MESSAGE) A signal driven by a target during the MESSAGE phase. REO (REQUEST) A signal driven by a target to indicate a request for a REQ/ACK data transfer handshake. ACK (ACKNOWLEDGE) A signals driven by an initiator to indicate an acknowledgement for a REQ/ACK data transfer handshake. ATN (ATTENTION) A signal driven by an initiator to indicate the ATTENTION condition. RST (RESET) An "OR-tied" signal that indicates the RESET condition. DB(7-8,P) (DATA BUS) Eight data-bit signals, plus a parity-bit signal which together form a data bus.

DB(7) is the most significant bit, and has the highest priority during the ARBITRATION phase. Bit number, significance, 'and priority decrease downward to DB(B). A data bit is defined as one when the signal value is true, and is defined as zero when the signal value is false. Data parity DP(P) is odd. The use of parity is a system option (i.e. a system is configure~ so that all SCSI devices on a bus generate parity and have parity detection enabled, or all SCSI devices have parity detection disabled or not implemented). Parity is not valid during the ARBITRATION phase. 5-3