omron — 2-step Acceleration/Deceleration Function

4-2 Function Mode 4 Functions •There's no indication of 2nd control functions on the display. You'll see which one is enabled by checking whether the terminal is turned on/off. •Switching the 2nd control using SET during operation does not work until the Inverter stops. 2-step Acceleration/Deceleration Function This function changes the acceleration/deceleration time during such operations. 4-52 Parameter No.

Function name Selection SET SP-SET A042/A242 Manual torque boost voltage Yes Yes A043/A243 Manual torque boost frequency Yes Yes A044/A244 V/f characteristics selection No Yes A045/A245 Output voltage gain No Yes A061/A261 Frequency upper limit Yes Yes A062/A262 Frequency lower limit Yes Yes A092/A292 Acceleration time 2 Yes Yes A093/A293 Deceleration time 2 Yes Yes A094/A294 2-step acceleration/deceleration selection Yes Yes A095/A295 2-step acceleration frequency Yes Yes A096/A296 2-step deceleration frequency Yes Yes b012/b212 Electronic thermal level No Yes b013/b213 Electronic thermal characteristics selection No Yes b021/b221 Overload limit selection No Yes b022/b222 Overload limit level No Yes b023/b223 Overload limit parameter No Yes b028/b228 Overload limit source selection No Yes C001 to C005/ C201 to C205 Multi-function inputs 1 to 5 selection No Yes C041/C241 Overload warning level No Yes H003/H203 Motor capacity selection No Yes H004/H204 Motor pole number selection No Yes H006/H206 Stabilization parameter No Yes Data Symbol Function name Status Description 09 2CH 2-step acceleration/deceleration ON Enables the 2-step acceleration/ deceleration time.

OFF Disables the 2-step acceleration/ deceleration time. Related functions C001 to C005 Required settings A092, A093, A094 = 00