omron — Extended function mode

Appendix-1 Parameter List * 2nd function is displayed when SET(08) is allocated to one of from C001 to C005. Extended function mode Appendix * 2nd control is displayed when SET (08) is allocated to one of from C001 to C005. App-2 Parameter No. Name Monitor or data range (Digital Operator) Default setting Changes during operation Unit Set value d102 DC voltage monitor 0.0 to 999.9 ⎯ ⎯ V d104 Electronic thermal monitor 0.0 to 100.0 ⎯ ⎯ % F001 Output frequency setting/monitor Starting frequency to 1st or 2nd max. frequency ⎯ Yes Hz F002 Acceleration time 1 0.01 to 99.99 100.0 to 999.9 1000. to 3000. 10.0 Yes s F202 *2nd acceleration time 1 0.01 to 99.99 100.0 to 999.9 1000. to 3000.

10.0 Yes s F003 Deceleration time 1 0.01 to 99.99 100.0 to 999.9 1000. to 3000. 10.0 Yes s F203 *2nd deceleration time 1 0.01 to 99.99 100.0 to 999.9 1000. to 3000. 10.0 Yes s F004 Operator rotation direction selection 00: Forward 01: Reverse 00 No ⎯ Parameter No. Function name Monitor or data range (Digital Operator) Default setting Changes during operation Unit Set value Basic setting A001 Frequency reference selection 00: Digital Operator (FREQ adjuster) 01: Terminal 02: Digital Operator (F001) 03: ModBus communication 10: Frequency operation result 00 No ⎯ A201 *2nd frequency reference selection 00 No ⎯ A002 RUN command selection 01: Terminal 02: Digital Operator 03:

ModBus communication 02 No ⎯ A202 *2nd RUN command selection 02 No ⎯ A003 Base frequency 30. to Max. frequency [A004] 60. No Hz A203 *2nd base frequency 30. to Max. frequency [A204] 60. A004 Maximum frequency 30. to 400. 60. No Hz A204 *2nd maximum frequency 60.