omron — Extended function mode

Appendix-1 Parameter List Appendix * 2nd control is displayed when SET (08) is allocated to one of from C001 to C005. App-14 Parameter No. Function name Monitor or data range (Digital Operator) Default setting Changes during operation Unit Set value Multi-function output setting C021 Multi-function output terminal P1 selection 00: RUN (signal during RUN) 01: FA1 (constant speed arrival signal) 02: FA2 (over set frequency arrival signal) 03: OL (overload warning) 04: OD (excessive PID deviation) 05: AL (alarm output) 06: Dc (disconnection detection) 07: FBV (PID FB status output) 08: NDc (network error) 09: LOG(logic operation output) 10: ODc (Do not use.) 43:

LOC (light load detection signal) 00 No ⎯ C026 Relay output (MA, MB) function selection 05 C028 AM selection 00: Output frequency 01: Output current 00 No ⎯ C031 Multi-function output terminal P1 contact selection 00: NO contact at MA; NC contact at MB 01: NC contact at MA; NO contact at MB 00 No ⎯ C036 Relay output (MA, MB) contact selection 01 C038 Light load signal output mode 00: Enabled during acceleration/deceleration/ constant speed 01: Enabled only during constant speed 01 No ⎯ C039 Light load detection level 0.0 to 2.0 × Rated current (0.0 setting: Function disable) Rated current No ⎯ Level output status setting C041 Overload warning level 0.0:

Does not operate 0.1 × Rated current to 2.0 × Rated current Rated current No A C241 *2nd overload warning level Rated current C042 Arrival frequency during acceleration 0.0 to 400.0 0.0 No Hz C043 Arrival frequency during deceleration 0.0 to 400.0 0.0 No Hz C044 PID deviation excessive level 0.0 to 100.0 3.0 No % C052 PID FB upper limit 0.0 to 100.0 100 No % C053 PID FB lower limit 0.0