3-7 Parameter List 3 Operation * 2nd control is displayed when SET(08) is allocated to one of from C001 to C005. Extended function mode * 2nd control is displayed when SET (08) is allocated to one of from C001 to C005. 3-21 Parameter No. Name Monitor or data range (Digital Operator) Default setting Changes during operation Unit Page d104 Electronic thermal monitor 0.0 to 100.0 ⎯ ⎯ % 4-4 F001 Output frequency setting/monitor Starting frequency to 1st or 2nd max. frequency ⎯ Yes Hz 4-5 F002 Acceleration time 1 0.01 to 99.99 100.0 to 999.9 1000. to 3000. 10.0 Yes s 4-5 F202 *2nd acceleration time 1 0.01 to 99.99 100.0 to 999.9 1000. to 3000.
10.0 Yes s 4-5 F003 Deceleration time 1 0.01 to 99.99 100.0 to 999.9 1000. to 3000. 10.0 Yes s 4-5 F203 *2nd deceleration time 1 0.01 to 99.99 100.0 to 999.9 1000. to 3000. 10.0 Yes s 4-5 F004 Operator rotation direction selection 00: Forward 01: Reverse 00 No ⎯ 4-6 Parameter No. Function name Monitor or data range (Digital Operator) Default setting Changes during operation Unit Page Basic setting A001 Frequency reference selection 00: Digital Operator (FREQ adjuster) 01: Terminal 02: Digital Operator (F001) 03: ModBus communication 10: Frequency operation result 00 No ⎯ 4-7 A201 *2nd frequency reference selection 00 No ⎯ 4-7 A002 RUN command selection 01: Terminal 02: Digital Operator 03:
ModBus communication 02 No ⎯ 4-7 A202 *2nd RUN command selection 02 No ⎯ 4-7 A003 Base frequency 30. to Max. frequency [A004] 60. No Hz 4-8 A203 *2nd base frequency 30. to Max. frequency [A204] 60. A004 Maximum frequency 30. to 400. 60. No Hz 4-9 A204 *2nd maximum frequency 60.