Accessories 12.3 SIRIUS infeed system for 3RA6 Combination with other sizes The infeed system for 3RA6 can be connected to the SIRIUS 3RV19 infeed system using the extension connector for 3RV19 (3RA6890-1AA). SIRIUS size S0 circuit breakers (max. 12.5 A / 400 V; I CU 45 mm adapter for the infeed system for 3RA6 (3RA6890-0BA). For additional information on combining the equipment with other sizes, please refer to "Configuration (Page 25)". 12.3.2 Coding the SIRIUS infeed system for 3RA6 The infeed system for compact starters can be locked by disabling the slots with a padlock (shackle diameter 3.5 - 4.5 mm). Simply attach a padlock to the fixture on the infeed system.

Figure 12-2 Locking the SIRIUS infeed system for 3RA6 for compact starters Alternatively, the infeed system for 3RA6 can be coded to only allow installation of compact starters with a defined maximum rated current. This function prevents compact starters being installed on the infeed system if their current setting range is too high, thereby eliminating the problem of infeed system current overload, for example. The infeed system for 3RA6 can be locked against compact starters with the following current setting ranges: ● 3 to 12 A ● 8 to 32 A ● 3 to 12 A and 8 to 32 A Procedure Coding is achieved by means of cylindrical pins (DIN EN ISO 8734-2x8).

The cylindrical pins are inserted into special holes in the infeed system's base carrier. The cylindrical pins are used as spacers and prevent compact starters from being snapped onto certain slots of the infeed system. SIRIUS 3RA6 Compact Starter System Manual, 02/2008, GWA 4NEB 560 0601-02 DS 02 97