MIL-STD 1808A (USAF) SYSTEM SYSTEM TITLE DEFINITION SUB- 21 AIR Continued CONDITIONING 60 TEMPERATURE The portion of the system used to control air CONTROL temperature within the cabin. Includes control valves, thermal sensing devices, switches, indicators, amplifiers, wiring, etc. 70 MOISTURE/AIR The portion of the system used to control moisture CONTAMINANT in the air, to control ozone concentrations, to filter CONTROL radioactive debris from conditioned air and to treat the air with deodorizers, insecticides, etc. 80 EQUIPMENT The portion of the system and its controls COOLING supplying cooled air to the equipment.
Includes the cooling unit, indicating systems related to the cooler operation, wiring, etc. Does not include temperature control and indicating systems. 90 LIQUID COOLING The portion of the system and its controls supplying cooling liquid to the equipment. Includes the compressor, coolant pump, indicating systems related to the operation, wiring, etc. Does not include temperature control and indicating systems. 23 Downloaded from https://www.everyspec.com