beckhoff TE1030 TwinCAT 3 — 7.3.13 Param

Markups On the other hand, the target group must be specified as "audience type" within the markup. Example Normal form: (*! This is a normal part of the documentation. This part is displayed for internal use only. *) If the target group has been set in both places, the documentation will be output accordingly. Currently, the two target groups "general" and "internal" are available. If you set the target group to "internal", the text within the markup will not be output to the documentation. 7.3.13 Param The markup Param allows to describe a parameter value of e.g. variable declarations.

It can be used optionally if there is not enough space behind the parameter definition in the declaration editor, or to have the complete documentation in the same place. The Param stands alone and does not need to be included in a Description, Summary or Example. The markup Param allows you to create a table in which the variables and their values are listed. Example Normal form: //! Some float var //! Some count var PROGRAM MAIN VAR_OUTPUT fFloatVar : REAL; iCount2 :INT; END_VAR Abbreviated form: TE1030 23 Version: 1.3.3