beckhoff TE132x — 5.1.1 Bode Plot - Architecture

Configuration | Bode Plot (Measurement) Bode Project: The main level, in which several Bode (or Scope) projects can be inserted. The Bode projects within a Measurement project can be controlled independently of one another. See also: Bode Plot - Project properties [ } 20] Bode project: All Bode Plots within a project are processed in parallel when a recording is started. When you click on a Bode project, the available properties are displayed in the Properties window. See also: Bode Plot properties [ } 20] Bode Plot: Every Bode Plot represents the connection with a drive axis. Several plots can exist in one Bode project.

The display area for a plot contains one chart each for the amplitude and phase responses, in which the already recorded or generated characteristic curves (sets) for the associated axis are displayed. While a recording is in progress, a third chart showing the current actual and setpoint values may be displayed. Apart from the connection data for the drive axis, the parameters for the next recording are also set via the Bode Plot. If you click on a Bode project, the setting options are displayed in the Properties window. See also: Bode Plot properties [ } 20] Set:

Each Bode Set corresponds to a recorded or generated frequency response and represents the resulting characteristic curves for amplitude and phase over frequency. Graphs can be displayed for the open and closed loops, as well as for the process. There are three types of sets: Record sets represent real recorded values Filter Sets represent the characteristic curve of a filter Result Sets represent the combination of two sets in order, for example, to get an idea of how a filter affects a frequency response. Among other things, the appearance, e.g. color and line width, can be adjusted in the Properties window. See also: Set Properties [ } 24] Markers:

Bode markers can be used to assist in the analysis of the recorded characteristic curves. These make it easier to read and compare the frequency responses in the MarkerWindow. See also: Bode Plot - marker properties [ } 29] Window The interfaces for the control of the Bode Plot are divided into several windows (Tool windows) and their position and size are freely configurable. TE132x 15 Version: 1.3.0