beckhoff TE132x — 5.1.3 Bode Plot - Toolbar

Configuration | Bode Plot WARNING Risk of injury due to the drive axis starting up automatically In order to create the Bode Plot recording, the drive axis executes a motion sequence that is dependent upon the settings. At the start of the Bode Plot recording the drive axis starts up automatically in accordance with the set motion profile and can endanger people and material. During the Bode recording the drive axis remains integrated in the application context (e.g. enables, monitoring, etc.). Ensure safety during the Bode Plot recording. If the toolbar is not visible by default or has been closed, it can be reactivated under View > Toolbars > TwinCAT 3 Bode.

The following elements are available by default in the toolbar: TE132x 19 Version: 1.3.0 Start Record: all plots connected to the selected Bode project start recording in parallel. The preset parameters are used to control the axes. Stop Record: all plots connected to the selected Bode project abort the recording. The connected drive axes are reset to the original operation mode.