Samples | TwinCAT 3 Bode Plot - first steps 5. The Bode Plot is started with the Start Record button in the Measurement toolbar. During the recording the current time signals are displayed below in the plot. You can abort the recording at any time with the Stop Record button. р If errors should occur during the recording, they are displayed in the Error List of the TwinCAT XAE Shell (or Visual Studio). For example, the Bode Plot reports a missing axis enable or the absence of a Dynamic Container when attempting to start the recording р However, the Error List only displays the errors output by projects that are part of the active solution. Example:
If a lag error is signaled for the drive axis and the project is not part of the active solution, a general Bode Plot error is output. If the project is part of the active solution, then the lag error is also output in the Error List. 6. You can change the display options in the Properties. For example, it may be useful to view the р Following the recording you can see all the characteristic curves created so far. "process" as well as the "open loop" and "closed loop" (see Open and closed loops [ } 11] ), or to highlight or mask individual characteristic curves.
For details on the settings, see the section “Bode Plot - set properties [ } 24] In addition, you can also add Filter Sets to simulate filters or Result Sets to determine superposition TE132x 36 Version: 1.3.0