Appendix | Return values TE132x 45 Version: 1.3.0 Code (Hex) Code (Dec) Symbol Description 0x8100 33024 INTERNAL Internal error 0x8101 33025 NOTINITIALIZED Not initialized (e.g.
no nc axis) 0x8102 33026 INVALIDPARAM Invalid parameter 0x8103 33027 INVALIDOFFSET Invalid index offset 0x8104 33028 INVALIDSIZE Invalid parameter size 0x8105 33029 INVALIDSTARTPARAM Invalid start parameter (set point generator) 0x8106 33030 NOTSUPPORTED Not supported 0x8107 33031 AXISNOTENABLED Nc axis not enabled 0x8108 33032 AXISINERRORSTATE Nc axis in error state 0x8109 33033 DRIVEINERRORSTATE IO drive in error state 0x810A 33034 AXISANDDRIVEINERROR- STATE Nc axis AND IO drive in error state 0x810B 33035 INVALIDDRIVEOPMODE Invalid drive operation mode active or requested (no bode plot mode) 0x810C 33036 INVALIDCONTEXT Invalid context for this command (mandatory task or windows context needed) 0x810D 33037 NOAXISINTERFACE Missing TCom axis interface (axis null pointer).
There is no connection to the NC axis. Either no axis (or axis ID) has been parameterized, or the parameterized axis does not exist. 0x810E 33038 INPUTCYCLECOUNTER Invalid input cycle counter from IO drive (e.g. frozen). The cyclic drive data are backed up by an ‘InputCycleCounter’ during the bode plot recording. This allows firstly the detection of an unexpected communication loss (keyword: LifeCounter) and secondly a check for temporal data consistency to be performed. Example 1: This error can occur if the cycle time of the calling task is larger than the assumed drive cycle time (in this case, however, the error occurs right at the start of the recording). Example 2:
This error can occur if the calling task has real-time errors (e.g. the "Exceed Counter" of the task increments or the task has a lower priority, as is often the case, for example, with the PLC). In this case the error can also occur at any time during the recording. Example 3: This error can occur more frequently if the real-time load on the computer is quite high (>50 %). Note: Refer also to the corresponding AX5000 drive error code F440.