Appendix | Third-party components Yes, there is no manufacturer limitation. How many measuring points should be selected for a meaningful representation? 10 to 20 per decade and of course more if necessary. Which measuring ranges are useful? 5 - 500 Hz in Velocity mode, 50 - 3000 Hz in Current mode. Does the NC cycle time have an effect on the Bode representation? The measured values are transmitted in so-called dynamic containers. Furthermore, the oversampling method ensures precise reproduction of the measured values. The NC cycle time should be around 2 ms. What system requirements must my PC fulfill? At least TC3.1X4016.x XAE and the system requirements associated with it.
Are open source software components used in TwinCAT Measurement products? Yes, various open source components are used. Please see the information on the page Third-party components [ } 48] . 7.3 Third-party components | Third-party components This software contains third-party components. Please refer to the license file provided in the following folder for further information: C:\Program Files(x86)\Beckhoff\Legal\TwinCAT-XAE-BodePlot TE132x 48 Version: 1.3.0