Up to version 1.1.xxxx.x | TE1410 Simulink Library Block output ports Block parameters TE1410 21 Version: 1.3.1 Data The value, read from the ADS variable Err Boolean flag signaling an actual ADS error ErrId The ADS error code Block sample time The Simulink block sample time, which is the ADS request interval (referred to the Simulink time but not to the real time) Abort simulation on ADS error Stop simulation at the first ADS error Data type The data type of the Data output signal, which should be the data type of the transmitted ADS variable Data width The width of the Data output signal. Use values greater than 1 to transmit arrays.
ADS timeout Simulink will wait on a response of the last ADS request until this time span is exceeded (in each time step) Direct feed through Evaluate the input values in the output method of the block. This ensures, that the values at the output ports in the current time step belong to the ADS parameters at the input ports of the same time step.