From version 2.x.xxxx.x | ADS in Simulink® The Const blocks carry the ADS address information here. The AMS Net Id is passed as an array, e.g. [192,168,226,1,1,1]. For Index Group and Index Offset please note that usually in TwinCAT (for example in the Target Browser) the information is given in hexadecimal. It is a good idea to use the hex2dec command, e.g. hex2dec('5DFF0'). Busy output feedback is used to prevent a next request from being made during one request. 3.6.1.3 Async ADS Write | Async ADS Write Asynchronous writing of an ADS symbol described at the input via AMS Net Id, Port, Index Group and Index Offset [ } 27] .
The read command is sent from Simulink ® with a positive edge at the trigger port. Port description Block Parameter TE1410 38 Version: 1.3.1 Port Name Data type Description Trigger boolean Block sends read command on positive edge. NetId uint8 AMS Net Id of the target system Port uint16 Port of the ADS device IndexGroup uint32 Index group IndexOffset uint32 Index offset Data configurable See Input Datatype and Dimension in Block Parameter Busy boolean TRUE from sending the request until receiving the response from the server Error int32 Error code