Beckhoff Automation GmbH & Co. KG TE1410 — 3.6.1.4 Async ADS ReadWrite

From version 2.x.xxxx.x | ADS in Simulink® Busy output feedback is used to prevent a next request from being made during one request. 3.6.1.4 Async ADS ReadWrite | Async ADS ReadWrite Asynchronous ReadWrite of an ADS symbol written at the input via AMS Net Id, Port, Index Group and Index Offset [ } 27] . The read command is sent from Simulink ® with a positive edge at the trigger port. Port description Block Parameter TE1410 40 Version: 1.3.1 Port Name Data type Description Trigger boolean Block sends read command on positive edge.

NetId uint8 AMS Net Id of the target system Port uint16 Port of the ADS device IndexGroup uint32 Index group IndexOffset uint32 Index offset Data configurable See Input Datatype and Dimension in Block Parameter Busy boolean TRUE from sending the request until receiving the response from the server Error int32 Error code Data configurable See Output Datatype and Dimension in Block Parameter Parameter Description Input Data Type TwinCAT primary data type, e.g. UINT, LINT, REAL, … Input Data Dimensions Dimension, e.g. 5, [2.3], … Output Data Type TwinCAT primary data type, e.g. UINT, LINT, REAL, … Output Data Dimensions Dimension, e.g. 5, [2.3], …

Block sample time [s] Sample Time of the block (Default -1 = Simulink Sample Time)