Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 2212A PULSE EMISSION (Transmitting tubes) 1. Procedure. The specified voltages shall be applied to the TUT. An essentially rectangular pulse voltage shall then be applied to the grid. Limits for the following shall be indicated on the TSS: a. Duration (tp); maximum. b. Time of rise and fall (tr), (tf); maximum. c. Slope at top of pulse; maximum. d. Ripple; maximum. e. Pulse repetition rate (pps). 2. Conditions. The voltage of the applied pulse shall be adjusted to give the specified cathode current, ik, at the leading edge of the pulse.

The ik from leading to falling edge shall not exceed the value specified (see 2212-1). 3. Equipment. The basic test circuit shown on figure 1372-1 shall be used. NOTE: tr and tf cannot be shown on the cathode current/time graph as these values refer only to grid voltage times. FIGURE 2212-1. Cathode pulse characteristics emission. METHOD 2212A 13 September 1972 2212-1