Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 3. Procedure B (for self-excited oscillator). 3.1 Circuit schematic. FIGURE 2214-1. Schematic for self-excited oscillator. NOTE: Above measurement system for an oscillator is similar to the right hand output half of the circuit block diagram shown for the power amplifier (procedure A). Comparable devices are used here for identical reasons defined in the amplifier circuit and test circuit diagram data. Oscillator frequency has to be measured, however, on the output side as there is no driver and oscillation is accomplished by coupling output energy into the input side of the TUT to sustain oscillation. a.
Dotted blocks are optional devices which may be used to initially establish appropriate circuit performance and frequency. b. Power measurements should be accomplished by either calorimetric or other suitable power techniques to an accuracy of 5 percent. 3.2 Test procedure. a. The electrode voltages are adjusted to the specified values and the grid current is observed to ensure that it does not exceed the specified value. b. The anode-to-grid feedback, and the output coupling are adjusted to obtain the highest possible output at the specified values of anode and grid currents. 3.3 Specified TSS test conditions. a. Value of grid bias resistor. b. Electrode voltages. c.
Anode current and range of grid currents. d. Frequency of oscillation (may be specified, or higher). 4. Alternative procedures. Procedures alternative to those of procedure A and procedure B are similar except the adjustments are made in order to obtain at least the specified value of output power, the electrode currents being within specified values. 4.1 Alternate specified TSS test conditions. a. Electrode voltages and value of grid resistor for oscillator. b. Frequency of rf output. c. Required level of output power. d. Maximum value of anode current. METHOD 2214B 19 September 1973 2214-2 e. Range limits for grid (and screen grid) currents.