Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 3216 GRID CURRENT (Thyratron) 1. With the tube operating under the specified conditions, for which the anode supply shall be a reversing voltage, the grid bias shall be increased in a negative direction to a value, Ecco (1), at which the tube just cuts off. The negative grid bias shall then be made zero, and the specified grid resistance shall be reduced to 10,000 ohms, and the anode current readjusted to the value specified. The grid bias shall again be increased in a negative direction to cutoff, Ecco (2). The grid current shall be computed from the following formula: