Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 3261 TIME JITTER This test is a measurement of the variation in anode firing time. Time jitter shall be determined by examining the scope presentation of the cathode current pulse as shown on figure 3261-1 and shall be measured at 50 percent of the pulse amplitude and shall not exceed the specified limit. In multigrid tubes, the time jitter shall be measured with respect to the trigger on the grid that receives the last pulse. FIGURE 3261-1. Cathode current pulse (leading edge) - time jitter. METHOD 3261 3261-1 19 April 1968