Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 3268B ENERGY DIVERTER (CROWBAR) OPERATION (Hydrogen modulators) 1. Energy diverter operation. In the test circuit as shown on figure 3268-1 the anode voltage shall be maintained and the tube triggered as specified. A tube which fires without being triggered is a failure. A tube which does not fire when triggered is also a failure. 2. Energy diverter anode delay time. Under the operation test conditions, the energy diverter anode delay time shall not exceed the specified value.