Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 3273 MODULATOR TEST, DUAL CONTROL GRID TETRODE THYRATRONS Dual control grid tetrodes. Dual control grid tetrode thyratrons shall be tested in the basic circuit shown on figure 3273-1. The respective grid drive amplitude and phasing shall be as specified on the TSS. NOTE: Include R V as part of R . FIGURE 3273-1. Basic modulator circuit for dual control grid switch tubes. METHOD 3273 19 April 1968 3273-1