Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4028 BAROMETRIC PRESSURE, REDUCED (Simulated high altitude) 1. Purpose. The purpose of this test is to determine that microwave tubes will perform suitably and are not subject to electrical breakdown in air insulated portions of input or output system, as specified, when operating at reduced barometric pressure. 2. Equipment. In addition to the normal operating equipment (as used in method 4250), the following equipment shall be needed: a.

A vacuum chamber with input and output feed-throughs capable of carrying the test voltages without arcing or corona from atmosphere down to the required pressure, or fixtures for specified input or output systems (see TSS) which permit continuous reduction of barometric pressure while operating. NOTE: The position of the ground plane relative to the tube must be specified if the test pressure is low enough to permit long path discharges. b. Mechanical pumps as required. c. Pressure gauges or manometers as required. 3. Procedure. 3.1 The tube shall be operated in the manner specified at normal ambient conditions.

If a variation of a parameter such as frequency is to be measured, an initial measurement shall be made after the temperature of the operating tube has stabilized. 3.2 While operation continues, the barometric pressure shall be reduced at the specified rate for: a. The whole tube in the chamber, or b. The specified input and output systems. 3.3 The tube is then allowed to stabilize at the final value and operate for 60 seconds. If required, a load VSWR of 1.5:1 shall be continuously varied through all its phases for the final 60 seconds. 4. Acceptance criteria. a.

When the variation of a parameter such as frequency is to be measured, both the maximum deviation and the final value of the specified parameter shall be within the limit(s) specified. b. There shall be no visible or audible corona or arcing at either the input or output. 5. Precautions. Because breakdown may occur at a pressure other than the final value due to long path discharges, observations should be conducted throughout the pressure cycle. Thus, if rate of change of pressure is non-linear, it shall be a continuous function from ambient to final value. METHOD 4028 4028-1 19 April 1968