Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4042 MICROWAVE MEASUREMENTS DURING SHOCK 1. Purpose. This test is designed to observe the effect of a physical shock on the performance characteristics of a microwave tube, while the tube is operating. 2. Equipment. The TUT shall be rigidly mounted on a suitable fixture or directly on the shock table using the normal mounting arrangement for the tube. If a fixture is used, it shall be designed so as to transmit the shock along the required axis. The shock input shall be monitored on the fixture at a point close to the attachment points of the tube.

Suitable equipment must be used to observe desired performance characteristics before, during, and after the shock impulse. In addition, the equipment must include a storage device which observes the selected operating characteristic during the shock impulse and holds it for subsequent reference. 3. Procedure. Testing shall be conducted in accordance with method 213 of MIL-STD-202 except that the tube will be subjected to one shock in each direction along three mutually perpendicular axes, for a total of six shocks in all. The operating characteristics are to be observed during each separate shock impulse. The individual TSS must specify the following. a.

The operating characteristic(s) which is to be observed during shock testing. Usually this will be power output. In addition, observations such as operating frequency, momentary electrical shorts, may be required. b. The operating voltages to be applied to the tube during testing. c. The shock pulse (shape, peak acceleration, and duration) selected from test condition in method 213 in MIL-STD-202. d. The failure criteria for each characteristic in a. above. 4. Precautions.

Prior to subjecting the tube to shock testing, the test instrumentation should be set up and checked under shock conditions in order to determine that the test instrumentation and connecting cable itself is unaffected by the shock impulses. This can best be accomplished by connecting the cabling to a nonoperating or dummy sample. 5. This is a nondestructive test. METHOD 4042 19 April 1968 4042-1