Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4223 MECHANICAL TUNING 1. Purpose. The purpose of this method is to test the mechanical characteristics of the tuning mechanism. 2. Definitions. 2.1 Mechanical tuning of microwave tubes is accomplished by changing the physical configuration of the resonant circuit(s) in a manner that changes the resonant frequency independently of any electrical or electronically induced frequency changes. 2.2 A tuning cycle is a complete excursion through the full tuning range and back to the starting point. 2.3 Tuning rate is the rate of change of frequency with respect to tuner position.
It may be specified in terms of the total tuner motion required to cover the specified frequency range. 2.4 Tuning speed is the number of complete tuning cycles which can be accomplished per second. 3. Equipment. Figure 4223-1 is a block diagram of the equipment required for these measurements. 4. Mechanical tuning range. The tube shall be capable of continuous operation over the specified frequency range. All other parameters shall remain within the specified limit(s). 5. Mechanical tuning rate. The tuning rate, and any discontinuity in tuning rate, shall be within the limit(s) specified. 6. Tuner torque or force. a. Starting torque or force.
The torque or force required to produce an initial frequency shift shall be within the limit(s) specified, over the tuning range. b. Operating torque or force. The torque or force required to maintain tuner motion shall be within the limit(s) specified, over the tuning range. c. Tuner stop endurance. The tuning mechanism shall withstand the specified torque (including impact values) at the limits of mechanical motion, without evidence of physical damage to the tuner drive mechanism, and shall meet the requirements of starting and operating torques. 7. Mechanical tuning fatigue.
The tube shall withstand the specified number of coarse or vernier tuning cycles without the tuning mechanism becoming inoperable. Unless otherwise specified, this test may be made on an inoperative or on a nonoperating tube. 7.1 This is a destructive test. 8. Resettability. The tuning dial shall be adjusted in one direction to a given setting, and the frequency measured. The tuner shall then be taken through the specified number of tuning cycles and returned to the given setting. a. From the same direction, and b. From the opposite direction. The frequency shall be reproduced within the specified limit(s) This test shall be performed in a manner which excludes thermal effects.
METHOD 4223 4223-1 19 April 1968