Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4251 OUTPUT POWER AND GAIN VARIATION (Microwave amplifier tubes) 1. Purpose. This test is designed to measure the variation in the output power and gain of a microwave amplifier tube as a result of a change in frequency, operating voltages, input power, magnetic field, or other operating conditions of the tube as specified. 2. Test circuit. FIGURE 4251-1. Output power variation. 3. Procedure. With the TUT inserted in the circuit shown on figure 4251-1, the output power is measured in accordance with method 4250 as the specified parameter(s) is varied.

The gain is measured in accordance with method 4253 as the specified parameter(s) is varied. 4. Precautions. 4.1 Appropriate filters shall be used for measurement of power output in accordance with method 4250. 4.2 Unless otherwise specified, under conditions wherein power output is to be measured into a load which is other than a matched load, the power output is defined as that power accepted by the load rather than that power incident upon the load. 4.2.1 In this case, the specified termination shall be as shown on figure 4251-2. FIGURE 4251-2. Alternate termination. METHOD 4251 19 April 1968 4251-1